capacitive displacement sensors, eddy-curent sensors capacitive sensors, eddy-current sensors, displacement sensors

Exact Match
site map
800-229-6544 • 651-484-6544 • info@lionprecision.com • 563 Shoreview Park Rd. • St. Paul, MN 55126, USA


ECL202 Eddy-Current Displacement Sensor

Performance

  • Nonlinearity: ±0.2%
  • Resolution: 0.008-0.1%FS @ 10kHz
    (probe dependent, see table below)
  • Bandwidth: to 15kHz
  • 0-10VDC Output

Features

  • Pushbutton Offset
  • Pushbutton Switch Threshold (Setpoint)
  • Range Indicating LEDs
  • Remote Offset and Threshold Activation
  • User-Selectable Bandwidth/Resolution
    100Hz, 1kHz, 10kHz, 15kHz
  • Plug&Play Sensor (TEDS) for use with LabView™

Below:

SpecificationsRange ChartMechanical Detail

Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration.

Resolution: See Range Table below for resolution
Linearity ±0.2% of Range
Bandwidth User Selectable, 15khz maximum
Driver Temperature Drift nonferrous U5 Probe

±0.08% F.S./°C

U8 Probe

±0.02% F.S./°C

U12 Probe

±0.03% F.S./°C

ferrous U5 Probe

±0.18% F.S./°C

U8 Probe ±0.04% F.S./°C
U12 Probe ±0.04% F.S./°C
Probe Temperature Drift nonferrous U5 Probe

±0.04% F.S./°C

U8 Probe

±0.01% F.S./°C

U12 Probe

±0.02% F.S./°C

ferrous U5 Probe

±0.10% F.S./°C

U8 Probe

±0.04% F.S./°C

U12 Probe

±0.06% F.S./°C

Analog Output

0-10VDC (typical), 0Ω

Switched Output

48VAC/70VDC/100mA

Input Power 15-28VDC
2.5W
Driver Operating Temperature 4°C-50°C
Probe Operating Temperatures

Standard Probes:
-25°C-+125°C

High Temperature Probes:
-25°C-+200°C

Ranges

calA specific range and resolution will require a particular probe size/model. Range/Resolution may also be affected by the target material.

Probes are identified by their diameter in mm.
A U5 probe has a 5mm diameter.Larger ranges require larger probes.

Custom ranges are always available.

Listed specifications are for standard target materials.

Range Chart

Range
mm
inch
Near Gap
mm
inch
Probe
Target
Type
Resolution (RMS)
µm
µinch
15kHz 10kHz 1kHz 100Hz
0.50
0.020
0.05
0.002
U3   TBD
1.25
0.050
0.25
0.010
U5 nonferrous 0.100
4.0
0.095
3.7
0.070
3.0
0.050
2.0
ferrous 0.170
7.0
0.160
6.0
0.120
5.0
0.090
4.0
2.00
0.080
0.35
0.015
U8 nonferrous 0.100
4.0
0.095
3.7
0.070
3.0
0.050
2.0
ferrous 0.140
6.0
0.130
5.0
0.040
4.0
0.070
3.0
3.50
0.140
0.60
0.025
U12 nonferrous 0.170
7.0
0.160
6.0
0.110
4.0
0.70
3.0
ferrous 0.250
10
0.230
9.0
0.170
7.0
0.120
5.0
5.00
0.200
0.75
0.030
U18 nonferrous 0.250
10
0.240
9.5
0.160
6.0
0.100
4.0
ferrous 0.300
12
0.280
11
0.190
8.0
0.120
5.0
8.00
0.320
1.25
0.050
U25 nonferrous 0.480
20
0.460
18
0.310
12
0.190
8.0
ferrous 0.480
20
0.460
18
0.310
12
0.190
8.0
12.5
0.500
1.50
0.060
U38   TBD
15.0
0.600
2.00
0.080
U50   TBD

Mechanical

eddy current sensor mechanical

ECL202 Manual
pdf (90K)

Eddy-Current Sensor Catalog
pdf (140K)

Minimum Target Thickness
web page pdf (50k)

ECL100 Master/Slave Configuration
web page pdf (28k)

-more TechNotes -

Not Yet Available

-more Application Notes -

 

© Lion Precision - All Rights Reserved