Eddy-Current Sensors

ECL150 & ECL150e Multi-Channel Eddy-Current Displacement Sensor

ECL150 Eddy-Current Displacement Sensor
ce

Performance

Features

Life-Cycle Status: Active

Survey Response

“I tested your Eddy Current sensors against 3 other brands for thermal stability & you were best by far.  Service and support have always been great.  Lion Precision is always very flexible and willing to meet our needs as they change.”

Export Requirements

Because of high resolutions, exports of the ECL150 may require an export license. The ECL150e has different resolution specifications and can ship without export license delays.

Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration. Specifications assume a target area at least three times the diameter of the probe.

Resolution:
RMS, Typical

Dependent on probe and range.
See Range Table for resolution specifics.

ECL150

0.006% RMS (Nonferrous);
0.008% RMS (Ferrous)

ECL150e

Greater of 0.3 µm or
0.006% RMS (Nonferrous);
0.008% RMS (Ferrous)

Linearity

±0.2% of Range

Error Band

±0.4% of Range

Maximum Bandwidth

15 kHz

Driver Temperature Drift
(15°C-50°C)

Typical. See Probe/Range chart for details.

nonferrous ±0.01% F.S./°C

ferrous ±0.01% F.S./°C

Probe Temperature Drift
(15°C-65°C)

Typical. See Probe/Range chart for details.

nonferrous ±0.01% F.S./°C

ferrous ±0.01% F.S./°C

Analog Output

±5 VDC, 0 Ω, 15 mA

Input Power

12 to 24 VDC,
1-2 Channels – 2.5 W
3-4 Channels – 3.5 W
5-6 Channels – 4.5 W
7-8 Channels – 5.5 W

Driver Operating Environment

4°C-50°C
IP64

Probe Operating Temperatures

Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets.

Other temperature ranges may be possible. Contact us for more information.

Standard Probes: IP67

High Temperature Probes: IP63

U3 Probe

Standard Probe (PUR Cable):
-25°C to +125°C
(Available with optional FEP cable)

High Temperature Version Not Available

U5-18 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +200°C

U25-50 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +175°C

 

Mechanical

Standard Model (with enclosure)

ECL150 Eddy Current Sensor Outline Dimensions

Model without enclosure

ecl150 dimensions without enclosure

Bookmark this page: Bookmark on del.ic.ous Bookmark on Google Bookmark on Yahoo Bookmark on Reddit Tweet this page Bookmark on Mr. Wong   Follow us: Lion Precision on LinkedIn Follow Us on Twitter Follow Us on YouTube