Eddy-Current Sensors

ecl100

ce

ecl110 eddy current sensor ECL110

Eddy-Current Displacement Sensor
ECL101 - Single Channel DIN Rail Mount
ECL110 - Multi-Channel No Enclosure

Performance

Features

Life-Cycle Status: Active

ECL110 Multi-Channel Version

The ECL110 is a multi-channel, OEM version of the ECL101. The ECL110 has no enclosure, is powered by a single power connection, and can have 1-8 channels internally synchronized with no need to for external sync cables.

Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration. Specifications assume a target area at least three times the diameter of the probe.

Resolution:

See Range Table for resolution specifications

Linearity

±0.50% of Range.

Temperature Drift of Probe at mid-range
(15°C-65°C)

±0.02% of Range/°F
±0.04% of Range/°C

Outputs

0-10 VDC
0-20 mA

Input Power

12-24 VDC
130 mA at 15 VDC

Operating Temperature

40°F-120°F
4°C-50°C

Probe Operating Temperatures

Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets.

Other temperature ranges may be possible. Contact us for more information.

Standard Probes: IP67

High Temperature Probes: IP63

U3 Probe

Standard Probe (PUR Cable):
-25°C to +125°C
(Available with optional FEP cable)

High Temperature Version Not Available

U5-18 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +200°C

U25-50 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +175°C

 

Mechanical

ECL101

sd

 

ECL110

ECL110 Outline Drawing

 

 

Bookmark this page: Bookmark on del.ic.ous Bookmark on Google Bookmark on Yahoo Bookmark on Reddit Tweet this page Bookmark on Mr. Wong   Follow us: Lion Precision on LinkedIn Follow Us on Twitter Follow Us on YouTube