Eddy-Current Sensors


ECD140 & ECD140e Eddy-Current Displacement Sensor for CompactRIO (National Instruments)

sd
ce


ecd140 displacement sensor video

The ECD140 plugs directly into a National Instruments
CompactRIO system for instant use with LabVIEW.

Performance

Features

Life-Cycle Status: Active

Export Requirements

Because of high resolutions, exports of the ECD140 may require an export license.

ECD140e

The ECD140e has different resolution specifications and can ship without export license delays.

LabVIEW, CompactRIO Drivers

Firmware Version

Demo Files

Manual

Rev 2

ECD14x-Basic-Rev-2.zip (0.8M)
ECD14x-Multi-Chan-Demo-Rev-2.zip (1.8M)

ECD140 Manual Rev 1 (250K pdf)

Intended Users

The ECD140 is intended for LabVIEW users experienced in FPGA and Real Time processor programming on the RIO platform. The device and the included software provide a tool kit for developers creating a complete system which requires precision noncontact displacement sensors. The system is not intended to be out‑of‑the‑box operational, but requires implementation and programming by experienced LabVIEW FPGA users.

Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration. Specifications assume a target area at least three times the diameter of the probe.

Resolution:

ECD140: 0.002-0.025% RMS @ 15 kHz
ECD140e1: 0.4 µm or higher RMS @ 15 kHz
Dependent on probe and calibration.
See Range Table for resolution specifications.

Linearity

±0.2% of Range

Error Band

±0.4% of Range

Bandwidth

15 kHz

Driver Temperature Drift

(15 °C-50°C)
nonferrous U8 Probe

±0.06% F.S./°C

U12 Probe
ferrous U8 Probe
U12 Probe

Probe Temperature Drift

(15 °C-65°C, except where noted)
nonferrous U8 Probe 0.02% F.S./°C
U12 Probe ±0.03% F.S./°C
ferrous U8 Probe ±0.04% F.S./°C
U12 Probe ±0.03% F.S./°C

Driver Operating Temperature

4°C-50°C

Probe Operating Temperatures

Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets.

Other temperature ranges may be possible. Contact us for more information.

Standard Probes: IP67

High Temperature Probes: IP63

U3 Probe

Standard Probe (PUR Cable):
-25°C to +125°C
(Available with optional FEP cable)

High Temperature Version Not Available

U5-18 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +200°C

U25-50 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +175°C

 

Bookmark this page: Bookmark on del.ic.ous Bookmark on Google Bookmark on Yahoo Bookmark on Reddit Tweet this page Bookmark on Mr. Wong   Follow us: Lion Precision on LinkedIn Follow Us on Twitter Follow Us on YouTube
© Lion Precision - All Rights Reserved