ECA110 Eddy-Current Displacement Sensor PCB for OEM and Embedded Applications
- Plug-in PCB
- 0-10V Output
- Factory Calibrated and Ready to Install
- Embedded Systems
- 12-24VDC Power
Specifications
Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration.
Resolution:
RMS at mid-range for most calibrations. See Ranges below for resolution details. |
DC-10kHz - 0.02% of range RMS |
| Nonlinearity |
See Output Curves in Range/Probe Section Below |
| Temperature Drift of Probe at mid-range |
±0.1% of range/°F
±0.2% of range/°C |
| Voltage Output |
Analog Voltage: 0-10V
|
| Input Power |
12-24VDC
30ma @ 15V |
| Operating Temperature |
40°F-120°F
4°C-50°C |
| Probe Operating Temperatures |
Standard Probes:
-10°F-+250°F
-25°C-+125°C
High Temperature Probes:
-10°F-+400°F
-25°C-+200°C |
Ranges/Probes
A specific range and resolution will require a particular probe size/model. Range/Resolution may also be affected by the target material.
Probes are identified by their internal coil diameter.
A U5 probe has a 5mm coil, U8 a 8 mm coil etc. Larger ranges require larger coils/probes.
Custom ranges are always available.
Listed specifications are for standard target materials.
Range Chart
Range
mm
inch |
Near Gap
mm
inch |
Probe
Model (Probe Diam.) |
Output Chart |
0.50
0.020 |
0.05
0.002 |
U3 (3mm) |
U3 Chart |
1.25
0.050 |
0.25
0.010 |
U5 (5mm) |
U5 Chart |
2.00
0.080 |
0.35
0.015 |
U8 (8mm) |
U8 Chart |
3.50
0.140 |
0.60
0.025 |
U12 (12mm) |
U12 Chart |
5.00
0.200 |
0.75
0.030 |
U18 (18mm) |
U18 Chart |
8.00
0.320 |
1.25
0.050 |
U25 (25mm) |
U25 Chart |
12.5
0.500 |
1.50
0.060 |
U38 (38mm) |
U38 Chart |
15.0
0.600 |
2.00
0.080 |
U50 (50mm) |
U50 Chart |
Mechanical