Eddy-Current Sensors

sd

ce

ECA101 Eddy-Current Displacement Sensor

The ECA101 is an updated replacement for the ECA100

Performance

Features

Life-Cycle Status: Active

Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration. Specifications assume a target area at least three times the diameter of the probe.

Resolution*:
RMS at mid-range

DC-10 kHz - 0.02% of range RMS

Linearity

Nonlinear - See Output Curves in Ranges/Probes

Temperature Drift of Probe at mid-range
(15°C-65°C)

±0.1% of range/°F
±0.2% of range/°C

Voltage Output

Analog Voltage: 0-10 V

Switch Output

Switch closure when output voltage is above adjustable setpoint:
30 VAC/60 VDC/100 mA

Input Power

12-24 VDC
2 W

Operating Temperature

40°F-120°F
4°C-50°C

Probe Operating Temperatures

Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets.

Other temperature ranges may be possible. Contact us for more information.

Standard Probes: IP67

High Temperature Probes: IP63

U3 Probe

Standard Probe (PUR Cable):
-25°C to +125°C
(Available with optional FEP cable)

High Temperature Version Not Available

U5-18 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +200°C

U25-50 Probes

Standard Probes:
-25°C to +125°C

High Temperature Probes:
-25°C to +175°C

*P-P resolution is 0.2%. In high EMI conditions (10 V/m), output level may shift and noise may rise to 600 mV RMS (6% resolution)

 